U-Prox CLC

Categories: ,

Description

An offline access device with a built-in touch request button. Support one
external reader series U-Prox SL and U-Prox mini (with BLE) with automatic interface setup when connected,
or non-BLE and IPR pre-configured RS232 readers. Supply voltage
+10,8 … + 15 V, 60 mA consumption. Inputs: door contact, external output request button. Outputs: relay 3 A / 24 V, alarm output open manifold, 24 V, 60 mA. Real-time clock, non-volatile memory. Configure with
U-Prox Mobile Config mobile application via Bluetooth. Supports 254 IDs + 1 Engineer Code,
memory for 1000 events, export log. Simple “day” / “night” schedule. Easy administration of access rights.